| Configuration | Safety Category | Rated Voltage | Application Scenarios |
|---|---|---|---|
| With black protective cap installed | CAT IV 600V / CAT III 1000V | 600V (Main power inlet) / 1000V (Distribution cabinets, motor circuits) | Industrial power distribution, cabinet primary circuit testing |
| Without protective cap (bare sharp probe) | CAT II 1000V | 1000V | Household outlets, secondary circuit testing inside equipment |
💡 Category Explanation: CAT IV > CAT III > CAT II. Higher categories deliver stronger protection against transient surges and short circuits. Always fit the protective cap for high-risk primary power measurements.
3. Compatible Instruments
Labelled compatible models: 3280, 3287, 3288 series. Full compatible lineup:
- 3280-10F / 3280-70F handheld digital multimeters
- 3287, 3288, 3288-20 portable digital multimeters
- CM3289, CM3291 AC/DC clamp meters
It adopts HIOKI proprietary multi-pin plug, incompatible with standard banana-jack multimeters.
4. Material & Structural Features
- Cable: Red & black double insulated heat-resistant wires, equipped with anti-bending strain relief to prevent cracking/wire breakage under frequent flexing
- Probe Handle: Ergonomic non-slip grey barrel with finger rest for stable grip during long-duration measurements
- Probe Tip: Removable black insulating cap, supporting safe high-voltage testing and narrow-space probing with bare tip
- Packaging: Individual blister & cardboard pack, marked with recyclable material logos (PET, PAP)
5. Application Scenarios
- AC/DC voltage, resistance and continuity testing for electrical maintenance & equipment commissioning
- Testing industrial distribution cabinets, motors, photovoltaic systems and household appliances
- High-precision on-site measurement paired with HIOKI clamp meters & portable multimeters
- Compliant with IEC 61010 international electrical safety standard, suitable for certified electricians’ field work
6. Genuine Product Identification Tips (Reference Photos)
- Crisp printing on original packaging, sharp HIOKI logo and neat barcode digits
- Complete voltage & specification markings printed on cable surface, resistant to rubbing off
- Neat injection-moulded plug without burrs; tight multi-pin contacts with no loose fit
- HIOKI L9208 Test Lead